devices.keithley:Keithley2450
Class for controlling Keithley 2450 SourceMeter.
Usage
devices.keithley:Keithley2450(
interface,
**kwargs,
)Provides methods to configure and control the Keithley 2450 source measurement unit for various sourcing and measurement operations.
Methods
| Name | Description |
|---|---|
| __init__() | Initialize the Keithley 2450 SourceMeter. |
| configure() | Configure the Keithley 2450 to source current and sense voltage. |
| getSense() | Get the current sense value from the instrument. |
| getSource() | Get the current source value from the instrument. |
| setSource() | Set the source value. |
__init__()
Initialize the Keithley 2450 SourceMeter.
Usage
__init__(
interface,
**kwargs,
)Parameters
interface: str-
VISA resource name for the instrument
**kwargs: dict- Additional arguments to pass to the VISA device initialization
configure()
Configure the Keithley 2450 to source current and sense voltage.
Usage
configure(
sourceMode=None,
senseMode=None,
fourWire=None,
senseAutoRange=None,
senseRange=None,
sourceAutoRange=None,
sourceRange=None,
senseLimit=None,
output=None,
delayAuto=None,
delay=None,
resetUnits=True,
reset=False,
)Parameters
sourceMode: str = None-
“VOLT” or “CURR”, physical parameter to source.
senseMode: str = None-
“VOLT” or “CURR”, parameter to measure.
fourWire: bool = None-
Four wire measurement; None uses the current configuration.
senseAutoRange: bool = None-
Autodetect the sense range.
senseRange: float = None-
Largest expected measurement value; the device picks the next inclusive range.
sourceAutoRange: bool = None-
Autodetect the source range.
sourceRange: float = None-
Largest expected source current; the device picks the next inclusive range.
senseLimit: float = None-
Voltage limit.
output: bool = None-
Turn the output on.
delayAuto: bool = None-
Automatically choose the delay for stabilizing the output.
delay: float = None-
Delay in seconds for stabilizing the output before doing an internal measurement. Does not affect other devices.
resetUnits: bool = True-
If True, Ampere and Volt are restored as default units for current and voltage measurements. Default is True.
reset: bool = False- If True, reset the device.
Examples
>>> device.configure(sourceMode="CURR", senseMode="VOLT",
... fourWire=True, senseAutoRange=True,
... sourceRange=0.001, output=True)Notes
The output will initially be turned off during configuration. This will configure the Keithley to be in 4W sense mode, detect the sense range automatically. The range is chosen to include 1mA and the output is turned on.
getSense()
Get the current sense value from the instrument.
Usage
getSense()Returns
float- The measured sense value
getSource()
Get the current source value from the instrument.
Usage
getSource()Returns
float- The measured source value
setSource()
Set the source value.
Usage
setSource(current)Parameters
current: float- The value to set for the source, either voltage or current depending on the source mode