devices.kepco:BOP5020mg
The device class for the Kepco BOP 50-20MG power supply.
Usage
devices.kepco:BOP5020mg(
interface,
**kwargs,
)It can possibly be used with different models with little changes.
Methods
| Name | Description |
|---|---|
| __init__() | Initialize the BOP5020mg device. |
| getCurrent() | Get the actual current at the device output. |
| getCurrentSetting() | Get the programmed value of current at the device output. |
| getVoltage() | Get the actual voltage at the device output. |
| setCurrent() | Set the output current in A. |
| setCurrentProtection() | Set the output protection current in A. |
| setCurrentWait() | Set the output current in A so the actual one is within tolerance. |
| setMode() | Set the output mode to current or voltage. |
| setOutput() | Set the output current ON or OFF. |
| setRemote() | Set the device to remote mode. |
| setVoltage() | Set the output voltage in V. |
| setVoltageProtection() | Set the output protection voltage in V. |
__init__()
Initialize the BOP5020mg device.
Usage
__init__(
interface,
**kwargs,
)Parameters
interface: str-
VISA resource name for the device
**kwargs: dict- Additional keyword arguments to pass to the VISA device
getCurrent()
Get the actual current at the device output.
Usage
getCurrent()Returns
float- Actual current in A
getCurrentSetting()
Get the programmed value of current at the device output.
Usage
getCurrentSetting()Returns
float- Set current in A
getVoltage()
Get the actual voltage at the device output.
Usage
getVoltage()Returns
float- Actual voltage in V
setCurrent()
Set the output current in A.
Usage
setCurrent(current)Parameters
current: float- Output current in A
setCurrentProtection()
Set the output protection current in A.
Usage
setCurrentProtection(
voltage,
resistance=0.8,
)Calculates the current from the applied voltage and the total resistance of the electromagnet.
Parameters
voltage: float-
Output voltage in V
resistance: float = 0.8- Total resistance of the electromagnet in Ohm, default is 0.8
setCurrentWait()
Set the output current in A so the actual one is within tolerance.
Usage
setCurrentWait(
current,
tolerance=0.4,
)Adjusts the current incrementally until the desired value is reached.
Parameters
current: float-
Output current in A
tolerance: float = 0.4- Tolerance for the actual current in A, default is 0.4
setMode()
Set the output mode to current or voltage.
Usage
setMode(mode)Parameters
mode: str- Takes “current” or “voltage” as input
setOutput()
Set the output current ON or OFF.
Usage
setOutput(output=None)Parameters
output: bool = None- True for ON, False for OFF
setRemote()
Set the device to remote mode.
Usage
setRemote()setVoltage()
Set the output voltage in V.
Usage
setVoltage(voltage)Parameters
voltage: float- Output voltage in V
setVoltageProtection()
Set the output protection voltage in V.
Usage
setVoltageProtection(
current,
resistance=0.8,
)Calculates the voltage from the applied current and the total resistance of the electromagnet.
Parameters
current: float-
Output current in A