devices.rohdeschwarz:FSW8

The device class for the Rohde & Schwarz FSW8 spectrum analyzer.

Usage

Source

devices.rohdeschwarz:FSW8(
    interface,
    reset=True,
    timeout=60000.0,
    **kwargs,
)

It can possibly be used with different models with little changes.

Attributes

Name Description
maxAverage The maximum average setting.

maxAverage

The maximum average setting.

maxAverage=1

The FSW8 will trigger that many sweeps, so the averaging requirement is satisfied.

Methods

Name Description
__init__() Initialize the device.
configureSweep() Change the sweep settings.
getData() Transfer measurement data from the VNA.
getSweepData() Prepare, trigger, and retrieve sweep data.
noise_cancellation() Turn noise cancellation on and off.
readSweepParams() Read the sweep parameters from the FSW8.
reset() Reset the FSW8 device.
setFreq() Set the center frequency and frequency span.
setStartStopFreq() Set the start and stop frequencies.
startSweep() Prepare the FSW8 for triggering a sweep.
trigger() Trigger the sweep(s).

__init__()

Initialize the device.

Usage

Source

__init__(
    interface,
    reset=True,
    timeout=60000.0,
    **kwargs,
)

Parameters

interface: str

The ip andress and port where the device is located. e.g. TCPIP::192.168.5.52::5025::SOCKET

reset: bool = True

If true, the PSA is reset on object creation using the reset method. Default is True.

timeout: int = 60000.0

The timeout of the ethernet connection in milliseconds. Default is 60e3 ms.

**kwargs
Keyword arguments passed to the VISAdevice constructor.

configureSweep()

Change the sweep settings.

Usage

Source

configureSweep(
    swePoints,
    refLev,
    resBW,
    vidBW=None,
    intpreamp=None,
    average=None,
    avgType="power",
    detector="rms",
    attAuto=True,
    attVal=0,
    sweType="fft",
    getData=False,
)

Frequency units are in Hz.

Parameters

swePoints: int

Number of points per sweep.

refLev: int

Reference level for a spurious emission measurement range.

resBW: int

Resolution bandwidth, decoupled from the span. In the Real-Time application the resolution bandwidth is always coupled to the span.

vidBW: int = None

Video bandwidth. If not None, the video bandwidth is decoupled from the resolution bandwidths.

intpreamp: int = None

Turns the internal preamplifier on and off; requires the optional preamplifier hardware. An activated external preamplifier disables the internal one, and vice versa. For R&S FSW 8/13 models the preamplification is defined by INPut:GAIN[:VALue].

average: int = None

Number of averages which make up the final values.

avgType: (power, linear, logarithmic) = "power"

‘power’ converts to Watt prior averaging, ‘linear’ averages before converting to logarithmic values, ‘logarithmic’ averages logarithmic power values. Default is ‘power’.

detector: (rms, log, scalar) = "rms"

‘rms’ power (RMS) averaging, ‘log’ log-power (video) averaging, ‘scalar’ voltage averaging. Default is ‘rms’.

attAuto: bool = True

If True, the attenuation is coupled to the reference level and set automatically for optimal internal data processing. Default is True.

attVal: int = 0

Total attenuation for RF input. Default is 0.

sweType: (fft, sweep, auto) = "fft"

Sweep type; ‘auto’ selects between sweep mode and FFT. Default is ‘fft’.

getData: bool = False
If True, trigger a sweep and return the results directly. Default is False.

Returns

numpy.ndarray or None
The sweep data if getData is True, otherwise None.

getData()

Transfer measurement data from the VNA.

Usage

Source

getData(precision="single")

Parameters

precision: str = "single"
One of {‘single’, ‘double’, ‘ascii’} ‘single’ and ‘double’ precisions are transferred as binary data, and achieve much faster transfer speeds. ‘ascii’ is only implemented as a fallback method, as it is much easier to debug. Default is ‘single’.

Returns

numpy.ndarray
The measured data from the device.

getSweepData()

Prepare, trigger, and retrieve sweep data.

Usage

Source

getSweepData()

This is a convenience method to prepare and trigger the sweep and transfer the data afterwards.

Returns

numpy.ndarray
The measured data from the specified channel.

noise_cancellation()

Turn noise cancellation on and off.

Usage

Source

noise_cancellation(state=False)

If noise cancellation is on, the R&S FSW performs a reference measurement to determine its inherent noise and subtracts the result from the channel power measurement result (first active trace only).

Parameters

state: bool = False
Whether to enable noise cancellation. Default is False.

readSweepParams()

Read the sweep parameters from the FSW8.

Usage

Source

readSweepParams()

Frequencies are returned in Hz.

Returns

tuple

A tuple containing (fStart, fStop, fPoints) where:

fStart : float The frequency at which the sweep starts. fStop : float The frequency at which the sweep stops. fPoints : int The number of points in the sweep.

reset()

Reset the FSW8 device.

Usage

Source

reset()

setFreq()

Set the center frequency and frequency span.

Usage

Source

setFreq(
    fCent,
    fSpan,
)

Parameters

fCent: float

The center frequency in Hz.

fSpan: float
The frequency span in Hz.

setStartStopFreq()

Set the start and stop frequencies.

Usage

Source

setStartStopFreq(
    fStart,
    fStop,
)

Parameters

fStart: float

The start frequency in Hz.

fStop: float
The stop frequency in Hz.

startSweep()

Prepare the FSW8 for triggering a sweep.

Usage

Source

startSweep()

The FSW8 disables the continuous trigger and therefore enables manual triggering. Any currently running sweeps are aborted.


trigger()

Trigger the sweep(s).

Usage

Source

trigger()